Coriolis Mass Flowmeter AMF008(TL4I)
Coriolis mass flowmeter is developed according to the principle of coriolis mass flowmeter, it can be directly measure parameters such as mass flow , density and temperature. It has been widely used in petroleum, natural gas, chemical, pipeline transportation industries. Its function is for trade settlement and process control to ensure precision reflection, enhanced safety and maintenance cost save.
Product Information
AMF series Coriolis meter’s mass flow can yield up to 0.15% accuracy. It is incredibly accurate and excellent repetition. And allows you as producer to make consistency and repeatability of batches.Direct mass flow. Do not lose the accuracy by measurement of T, P, Z &ρand Volume conversion.It can measure more than one variate in the tube. Such as mass flow, volume flow, density, concentration, temperature and viscosity.It’s lower maintenance. There is no moving parts in Coriolis meter and no impellers and obstructions in the line. So, There is no movement and wearing mar. The meter’s last forever.Measure high viscosity and non- Newtonian fluid, besides homogeneous fluid, not only single phase fluid can be measured, but also homogeneous multi- phase fluid.Good antiseptic property, various common corrosion fluids can be measured.
General tech Parameter
– Accuracy Grade 0.15, Grade0.2, Grade0.5, Grade1.0……
– Density ±0.001g/cm3
– Ambient temp -25℃~+55℃
– Relative humidity ≤95%
– Measuring medium Gas,Liquid
– Medium temp Cryogenic: -196℃~+70℃;
– Normal temp.: -40℃~+70℃
– Meter tube mat’l 316L
– Output Modbus/RS-485:
1. The default baud rate is 38400bit/s. Refer to table 3 for details.
2. Pulse output signal:
3. Passive: Open collector, max 36VDC,100mA,electric isolation.
4. Pulse output: The value is optional. Pulse polarity is positive.
5. Refer to table 5 for details.
6. Current output(only for with display):
7. Passive: 4~20mA HART. Power: 12VDC~40VDC
8.RL<700Ω, Resolution ratio: 2.24uA
– Power voltage 12VAC~30VAC / 15VDC~40VDC
– Elect. Conn M20×1.5
Standard parameter of communication of Modbus/RS-485
– Protocol Modbus Protocol
– Device Type Slave for the device
– The range of address 1…247
– Broadcast address 170
– Function code 03:Read holding register
04:Read input register
06:Read-in single register
16:Read-in multiple register
– Support baud rate 1200, 2400, 3600, 4800, 9600, 19200 , 38400 (default) , 57600 , 115200 ( BAUD)
– Data transfer mode RTU
– Data access Access device parameter through Modbus/RS-485 (Refer to Appendix C for information of Modbus register)
Installation
Installation Instruction
a. The flowmeter shall be installed firmly and mounted on the support frame, and no obvious vibration source is allowed in the installation area. The ambient temperature shall be in the range of -25℃ to +55℃, and effective measures shall be taken for rain-proof and water-proof.
b. In case the measured medium is gas, please refer to article “installation type” for recommended installation type.
3.In case the measured medium is liquid, please refer to “installation type” for recommended installation type.
c. The wiring terminal of the transmitter is in the wiring chamber of the transmitter, the wiring terminal can be seeing when the wiring cover of the transmitter is open.
Installation Methods
a. When measure gas: horizontal upwards or vertical, horizontal upwards refers to the meter tube (inside the housing) should be located upward, and upside-down is forbidden.
b. When measure liquid: horizontal downwards or vertical, horizontal downwards refers to the meter tube (inside the housing) should be located downward, and upside-down is forbidd